Jet Pump Pedrollo JCR1C Suitable for user with clean water and with liquids that are not chemically aggressive towards the materials from which the pump is made. The self-priming JCR pumps are designed to pump water even in cases where air is present. This Pump recommended for use in domestic applications such as the distribution of water in the irrigation of gardens and orchards, etc. The pump should be installed in an enclosed environment or sheltered from inclement weather.
Performance Range :
- Flow rate up to 60 l/min (3.6 m³/h)
- Head up to 48 m
Application Limits :
- Manometric suction lift up to 9 m (HS)
- Liquid temperature between -10°C and +40°C
- Ambient temperature between +40°C
- Maximum working pressure 6 bar
- Continuous Service S1
FEATURES :
COMPONENT | CONSTRUCTION CHARACTERISTICS | ||||
PUMP BODY | Staninless steel AISI 304 complete with threaded ports in compliance with ISO 228/1 | ||||
BODY BACKPLATE | Stainless steel AISI 304 | ||||
NOZZLE ASSEMBLY | Noryl FE1520PW | ||||
IMPELLER | Stainless steel AISI 304 | ||||
MOTOR SHAFT | Stainless steel EN 10088-3-1.4104 | ||||
MECHANICAL SEAL | Seal | Shaft | Materials | ||
Model | Diameter | Stationary ring | Rotational ring | Elastomer | |
AR-12 | ø 12mm | Ceramic | Graphite | NBR | |
BEARINGS | 6201 ZZ / 6201 ZZ | ||||
CAPACITOR | Pump | Capacitance | |||
Single-phase | (230 V or 240 V) | (110 V) | |||
JCRm 1C | 10μF 450 VL | 25 μF 250 VL | |||
JCRm 1B | 10μF 450 VL | 25 μF 250 VL | |||
JCRm 1A | 14μF 450 VL | 25 μF 250 VL | |||
ELECTRIC MOTOR | JCRm : Single-phase 230 V – 50 Hz with thermal overload protector incorporated into the winding | ||||
JCR : three-phase 230/400 V- 50 Hz |
Technical Specification of Jet Pump Pedrollo JCR1C :
- Model : JCR 1C
- Three phase / 380V
- Port : 1 Inch
- Weight : 7.1 kg
- Capacity :
0.3 m3/h 5 l/min ; Head 32 m
0.6 m3/h 10 l/min ; Head 28.5 m
0.9 m3/h 15 l/min ; Head 23.5 m
1.2 m3/h 20 l/min ; Head 21 m
1.5 m3/h 25 l/min ; Head 18.5 m
1.8 m3/h 30 l/min ; Head 15 m
2.4 m3/h 40 l/min ; Head 13.5 m
2.7 m3/h 45 l/min ; Head 12 m
3.0 m3/h 50 l/min ; Head 10 m